IC card diaphragm gas meter
Product overview
The IC card diaphragm gas meter is an integrated intelligent gas meter with IC card for prepayment and automatic charging of gas meter.
The product has dual synchronous display of mechanical counter and electronic counter with the advantages of beautiful shape, accurate measurement, clear and convenient reading, easy to use, and so on. IC card adopts logical encryption to ensure information security. Gas meter sale management system can store all initial file information of the user gas meters as needed, such as the gas meter factory No., constant, user address, which could solve the problems of household meter reading and charge difficulty in gas company in order to improve the management level and work efficiency. It is an ideal measuring instrument to meet the needs of modern gas management.
Main advantages
1.Advanced anti-jitter technology, full-sealing treatment
2.Dual display of mechanical character wheel and liquid crystal
3.The use of double dry spring tube for sampling to meter gas consumption accurately
4.Amount / air sales, support for step gas price
5.Magnetic transmission, seal well
6.Antimagnetic interference
7.Good anticorrosion performance, gas meter and its built-in valve have passed the certification by national anti-explosion organization
8.Super low power consumption, battery life more than 1 year
9.Upload information (through IC card)
10.Prevent gas storage
11.Logical encryption to protect data security
12.The gas meter corresponds to the user card one by one to prevent the channeling use
13.Failure alarm prompt
 
Executive standard
1.GB/T6968-2011 "Diaphragm gas meter"
2.CJ/T112-2008 "IC card diaphragm gas meter"
Main Parameters 
Item Unit Specification model /
Performance index
CG-L-1.6-Ab CG-L-2.5-Ab CG-L-4-Ab
Max. flow rate qmax m3/h 2.5 4 6
Min. flow rate qmin m3/h 0.016 0.025 0.04
Basic error difference
qmin≤q﹤0.1qmax
% ±3 ±3 ±3
Basic error difference 0.1qmax≤q≤qmax % ±1.5 ±1.5 ±1.5
Max. working pressure kPa 10 10 10
Total Pressure absorption Pa ≤250 ≤250 ≤250
Pipe joint spacing mm 130 130 130
Operating current μA ≤100
Working voltage V DC-6V
Using ambient temperature oC -10 ~ 40
Count range m3/h 0-99999.9998 m3
Margin insufficient prompt m3/h Self-set
External thread size - M30*2 M30*2 M30*2
Other functions - Real time temperature compensation
Pressure compensation
(Optional)